This is a photo of a sheet metal flex duct for a bathroom exhaust fan. The bath room exhaust fan is the ceiling mounted fans that are put in place to relive the bathroom of steam and humidity from hot showers. By venting this steam and humid air into the attic the possibility of mold development is increased. These ducts should be vented out through the roof or to a soffit vent.

 

This is an example of what can happen when vent pipes and roof vents have flashing that is improperly installed. There are many roofing companies that are not familiar with the proper way to install flashing etc. etc. In the photo you can see the dark area in the roof sheeting around the white pipe this area is very soft wood that is now in a state of Dry Rot. This wood is very attractive to all wood destroying organisms and is no longer structurally sound.

 

When down spouts are located in area where they drain next to the foundation of a house there should be a splash block installed to prevent the water from washing way the soil from the foundation. It is recommended that when ever possible, down spout termination points should be routed away from the foundation.

 

Metal ridge vents are very common for attic ventilation although if not nailed properly they can be a prime area for roof leaks. The most recent practice is to use special screw with rubber washers or aluminum ring shank nails with rubber washers. In the case of some older roofs the nail heads must be caulked to prevent the nail from backing out and causing a roof leak.

 

In this photo you see a similar problem with an exposed nail head on the top of a shingle tab. This will result in a roof leak if the nail head is not caulked and the caulking is maintained on an annual basis. (Nail heads should never be exposed any where on the roof)

 

This is an example of a vent pipe that has been improperly installed. The black roofing tar has been applied to help prevent a roof leak. The problem here is the part that you can not see. Under the tar the metal flashing should fit under the shingles on the top and sides but on the bottom side the flashing should be on top of the singles so that any leaks from the top or side will flow over the shingles not .

 

In this photo we see how the flashing for a roof vent should be installed. The problem is that we see here that we have exposed nail head that should not be there. At this point Caulking the nail heads is the best thing to do.

 

All exterior outlets must have weather proof covers. A wet outlet and a small child is not a good combination. There are many different kind of exterior outlet cover available and for the few dollars and few minutes it take to install and new cover is well worth the time.

 

Here we seen an item that most everyone is familiar with although most people are not aware of the Fire Protection Code that this drop stair effects. Code requires that all walls and ceiling in the garage be covered and sealed completely with 1/2 inch or grater sheet rock. Drop stairs are covered with a thin piece of wood paneling that will allow a fire to spread

 

This photo shows the inside of an air handler that has an improper size and style of air filter. In this case this was the only air filter for the entire heating and cooling system, and as you can see this air filter is not filtering any air. Note: the air filter is the blue fibrous square in the middle of the photo

This is one of the most common items found with exterior doors. As you can see at the bottom corner of the door and the door frame there is some dark staining that staining is actually dry rotted wood. This is most often found at garage passenger doors and pool bath exit doors. These areas can be

 

The vast majority of wood fences are not installed or maintained to reach there peak life span. #1. the bottom of the 4 x 4 post should be wrapped in tar paper & or coated with roofing tar then set in concrete with 2” of concrete above grade. #2 the fence boards should be 2”+ above grade as to not wick moisture up the fence boards. #3 even though most fence

 

It is highly recommend that all double garage door have two tension springs.

Asphalt composition shingles must be installed on a minimum of 2-12 pitch roofs. The pitch in the middle of this photo is not Proper for asphalt composition shingles. Some of the materials that could be used are: rolled asphalt roofing, rubber membrane, or tar built up. The use of current shingles

In This photo we see an electrical Panel box with a open slot at the lower left corner. This open slop gives an improperly placed finger access to the buzz bar, touching this bar can cause serious injury and/or death. The simple repair of this item is to insert an electrical panel box blank slot cover

 

Seen here is one of the most, common problems found in side electrical panel boxes. As you car see there is two wires connected to one breaker, this is a fire safety hazard. In this case a double breaker can be added to allow for two wires.

 

Obviously this photo shows a broken truss webbing member. This can be a major concern when hurricane season comes around. This is very easily repaired by what called side is scabbing with 2x4’s on each side of the truss webbing member.

 

Roof life spans are reduced in this area of Florida due to our hot summers and heavy rainy season. In the photo we see a Palm tree that was planed too close to the house. As a Young tree it posed no threat but now as a near adult tree it is acting as a brume sweeping away the protective gradual

 

Asphalt composition shingles must be installed on a minimum of 2-12 pitch roofs. The pitch in the middle of this photo is not Proper for asphalt composition shingles. Some of the materials that could be used are: rolled asphalt roofing, rubber membrane, or tar built up. The use of current shingles will

 

Roof vent pipes of all kinds should be installed so that the bottom side of the flashing boot is installed over the top of the shingle to the bottom side. In this photo we can not identify the Proper installation so it is recommended to keep a water tight seal around the vent pipe. This caulking seal

 

In this photo we see a similar problem to the issue with the attic drop stairs. Fire safety code requires that the garage walls and ceilings are to be sealed with 1/2 inch dry wall with Fire rated mud and tape. We see in the photo opening

 

wp039759fb.png
wp296c898a.png
wp2a0694fa.jpg
wpc776be72.png
wpc20c0b28.jpg
wpa8884002.png
wp791d5bf4.jpg
wp6c476473.png
wpa139ced2.jpg
wp6f9a73d6.png
wpd95ea02e.jpg
wp0b7bd264.png
wp5dc99554.jpg
wpd3fc7799.png
wpc799467e.jpg
wp24fafa8f.png
wp4cb962ef.png
wp26dd8e58.jpg
wp406d4b35.jpg
wpfc1e614a.png
wp753d60da.jpg
wp5ae7b781.png
wp38b03212.jpg
wpcaf59f72.png
wpcc74d14b.jpg
wpd848a111.png
wpf97c1e0b.jpg
wpa837d9b1.png
wp76f3bcf0_0f.jpg
wpdda2b24d.png
wpfee1bba0.jpg
wp59f54785.png
wp9742b66e.jpg
wpb866337f.png
wpf0478044.jpg
wpa9a968b2.png
wpe5359d53.jpg
wp987bc85a.png
wp3b516dde.jpg
wp1e38e6c8.png
wp943bfc94_0f.jpg

MOST COMMON ITEMS FOUND DURING INSPECTION

 

wpfc439c33.jpg

under the shingles. If a leak occurs in this case the roof sheeting will be damaged as well as the insulation and the ceiling sheet rock

to the attic and the rest of the house much faster then the proper sheet rock. This does not necessarily mean you must replace it but it does mean you must be aware of the safety issues concerning it.

properly repaired. The moisture accesses this area due to short roof over hangs and lack of threshold slope.

boards and post are treated it is highly recommended that the fence be treated once per year with a wood sealer.

will lead to a fast deterioration of shingles and roof leaks.

that is made to fit the panel box of the manufacturer.

off of the shingles. The palm fauns will need to be timed often or the tree will need to be relocated further away from the house.

lead to a fast deterioration of shingles and roof leaks.

will need to be inspected regularly and caulk will need to be removed and re caulked as the old caulk dries out.

in the dry wall ceiling that can allow a fire to more easily access the attic.